0
1.5kviews
Electronic Instruments and Measurements : Question Paper May 2012 - Electronics Engineering (Semester 3) | Mumbai University (MU)
1 Answer
0
4views

Electronic Instruments and Measurements - May 2012

Electronics Engineering (Semester 3)

TOTAL MARKS: 80
TOTAL TIME: 3 HOURS
(1) Question 1 is compulsory.
(2) Attempt any three from the remaining questions.
(3) Assume data if required.
(4) Figures to the right indicate full marks.


Any Four :-

1 (a) A PMMC instrument has FSD of 100 ?A coil resistance is 1 k?. Calculate the required shunt resistance value to convert the instrument in to an ammeter with (i) FSD=100 mA (ii) FSD=1A(5 marks) 1 (b) What is difference between electrical instruments and electronic instruments?(5 marks) 1 (c) Explain basic principle of frequency meter(5 marks) 1 (d) When oscilloscope time is disconnected and various types of signals are connected to vertical and horizontal inputs then draw displays.
Verticale I/P Horizontal I/P
(i) Sine Wave OV
(ii) Sine Wave Gine wave?.same 'f' 0° phase
(iii) Sine Wave antiphase sine wave
(iv) Sine Wave Sine Wave with 90° phase. same frequency
(5 marks)
1 (e) What is Megger? Explain its working(5 marks) 2 (a) What is ohmmeter? Explain working principle of series and shunt ohmmeter. Also compare them. Comment on calibration of ohmmeter.(10 marks) 2 (b) What is resolution and sensitivity of digital voltmeter? Explain working principle with block diagram of successive approximation type DVM.(10 marks) 3 (a) Explain with the block diagram basic elements of a laboratory type function generator. Which is the basic function generated? How? How frequency is controlled? How sine function is generated?(10 marks) 3 (b) Explain with the block diagram basic elements of digital phase meter. How the meter tells about which waveform is leading or logging? Mension limitations of this type of meter(10 marks) 4 (a) What is the need of time base generator in standard CRO? How the time base signal is generated? What is delay line? Why it is neede? Why some times the triangular wave observed in CRO moves left or right continuously? How to stabilise it? What actually happens when we get steady waveform on CRO?(10 marks) 4 (b) What is z-modulation in CRO? For what purpose it is used? Can frequency and phase difference be-measured using z-modulation?(10 marks) 5 (a) What is Q meter? Explain its working principle with the help of circuit diagram(10 marks) 5 (b) What are the two types of connections for measuring resistance using voltmeter, ammeter method? Compare the two methods.
If voltmeter is connected across supply type connection the measured current is 0.5 A and voltmeter indication is 500 V. Ammeter has a resistance Ra-10&OMega;. Calculate the value of 'R'
(10 marks)
6 (a) With reference to the characteristics and applications, differentiate between D.C. shunt and series motors(10 marks) 6 (b) Explain the principle of operation of PMMC and moving iron type of instruments. Compare the two basic types.(10 marks) 7 (a) What are the various torque required in PMMC? How they are generated? What is the requirement of each of the torque?(10 marks) 7 (b) Draw only the Kelvin's double bridge(6 marks) 7 (c) Explain in short basic principle of working of stepper motor?(4 marks)